FM 900 OPEN CHANNEL FLOW MEASUREMENT SYSTEM
Non-Contact Flow Monitoring for all flumes and weirs


The FM 900 provides accurate non-contact ultrasonic open channel flow measurement.
Simple programming allows selection from a list of common built-in weir and flume tables. In addition,
head vs. flow data points may be input for almost any type of primary device.

The integral display and keypad allows for fast, simple programming and operational indication.
A real time clock and datalogging capabilities allow up to 6 months of flow information to be
stored in memory.

Adjustable damping, transducer transmit power, and low flow cutout provide flexibility in difficult
monitoring applications.


FM 900 FEATURES

• Simple menu driven programming
• Large, backlit, multi-function LCD display
• Integral 5-position keypad
• 4-20mA and 3 relay outputs
• Integral datalogging with RS-232C output
• Built-in weir and flume tables
• Sampler trigger output
• Full diagnostics
• Intrinsically safe sensor suitable for use in hazardous locations
• Submersible sensor with temperature compensation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FM-1000 OPEN CHANNEL FLOW MEASUREMENT SYSTEM

Non-Contact Flow Monitoring for all flumes and weirs Choose from the FM1000D remote mounted LCD indicator or the FM1000C chart recorder with vacuum flourescent display.
The system totalizes and computes flow for a wide variety of primary devices. Both systems include the field-proven FM-1000US Ultrasonic Level/Flow Sensor.


FM-1000D LCD INDICATOR / TOTALIZER SPECIFICATIONS

• Display: 2-line LCD
• Keypad: 3-button for programming and data display selection
• Input: 4-20 mA
• Output: User configurable relay
• Temperature Range: -22 F to +178 F
• Accuracy +- 0.05% of span
• Sensor Power Supply: 24VDC @ 50mA
• Power Input: 80-240 VAC
• Enclosure: NEMA 4X wall mount


FM-1000C INDICATOR, TOTALIZER & RECORDER SPECIFICATIONS

• Display: 2-line Alphanumeric Vacuum Flourescent
• Keypad: 4-Button for Programming and Data Display Selection
• Input: 4-20 mA
• Temperature Range: 0-140 F
• Accuracy: +- 0.05% of Span
• Memory: Non-Volatile
• Chart Size: 10”
• Chart Rotation: 24 Hour or 7 Day
• Transducer Power Supply: 24VDC @ 230 mA
• Power Input: 115 VAC
• Enclosure: NEMA 12 Wall Mount

FM-1000US SENSOR SPECIFICATIONS

• Transducer Housing: Corrosion Resistant Polypropylene
• Measurement Range: 20 Ft. Maximum
• Accuracy +- 0.5% of Measured Level
• Resolution: +- 0.04”
• Temperature Range: -20 to 140 F
• Weight: 1.5 Lbs.
• Enclosure: NEMA 6
• Output: Isolated 4-20 mA
• Power Requirements: Two Wire Loop Powered
• Process Connection: 2” NPT FM-1000US FEATURES
- Removable LCD Programmer.
- Narrow 5 degree beam angle suitable for small throat flumes.
- 10” deadband is ideal for minimal headroom applications.
- Built-in Head vs. Flow tables for standard weirs and flumes.
- 32-point linearization input for custom applications
- No special wiring. Uses standard shielded two-wire signal cable up to 2000 ft long.
• Temperature Range: -22° F to 150° F
• Weight: 1.5 Lbs.
• Options: Loop powered scalable 4-20mA output, AC powered w/2 relay outputs, explosion proof, dual sensor input


. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
 