FM
900 OPEN CHANNEL FLOW MEASUREMENT SYSTEM
Non-Contact Flow Monitoring for all flumes
and weirs
The FM 900 provides accurate non-contact
ultrasonic open channel flow measurement.
Simple programming allows selection from
a list of common built-in weir and flume
tables. In addition,
head vs. flow data points may be input
for almost any type of primary device.
The integral display and keypad allows
for fast, simple programming and operational
indication.
A real time clock and datalogging capabilities
allow up to 6 months of flow information
to be
stored in memory.
Adjustable damping, transducer transmit
power, and low flow cutout provide flexibility
in difficult
monitoring applications. |
 |
FM 900 FEATURES
• Simple menu driven programming
• Large, backlit, multi-function LCD display
• Integral 5-position keypad
• 4-20mA and 3 relay outputs
• Integral datalogging with RS-232C output
• Built-in weir and flume tables
• Sampler trigger output
• Full diagnostics
• Intrinsically safe sensor suitable for
use in hazardous locations
• Submersible sensor with temperature compensation |
. . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . |
FM-1000
OPEN CHANNEL FLOW MEASUREMENT SYSTEM
Non-Contact Flow Monitoring for all flumes
and weirs Choose from the FM1000D remote
mounted LCD indicator or the FM1000C chart
recorder with vacuum flourescent display.
The system totalizes and computes flow
for a wide variety of primary devices.
Both systems include the field-proven FM-1000US
Ultrasonic Level/Flow Sensor.
FM-1000D LCD INDICATOR / TOTALIZER
SPECIFICATIONS
• Display: 2-line LCD
• Keypad: 3-button for programming and
data display selection
• Input: 4-20 mA
• Output: User configurable relay
• Temperature Range: -22 F to +178 F
• Accuracy +- 0.05% of span
• Sensor Power Supply: 24VDC @ 50mA
• Power Input: 80-240 VAC
• Enclosure: NEMA 4X wall mount |
 |
FM-1000C INDICATOR,
TOTALIZER & RECORDER SPECIFICATIONS
• Display: 2-line Alphanumeric Vacuum Flourescent
• Keypad: 4-Button for Programming and
Data Display Selection
• Input: 4-20 mA
• Temperature Range: 0-140 F
• Accuracy: +- 0.05% of Span
• Memory: Non-Volatile
• Chart Size: 10”
• Chart Rotation: 24 Hour or 7 Day
• Transducer Power Supply: 24VDC @ 230
mA
• Power Input: 115 VAC
• Enclosure: NEMA 12 Wall Mount
FM-1000US SENSOR SPECIFICATIONS
• Transducer Housing: Corrosion Resistant
Polypropylene
• Measurement Range: 20 Ft. Maximum
• Accuracy +- 0.5% of Measured Level
• Resolution: +- 0.04”
• Temperature Range: -20 to 140 F
• Weight: 1.5 Lbs.
• Enclosure: NEMA 6
• Output: Isolated 4-20 mA
• Power Requirements: Two Wire Loop Powered
• Process Connection: 2” NPT FM-1000US
FEATURES
- Removable LCD Programmer.
- Narrow 5 degree beam angle suitable for
small throat flumes.
- 10” deadband is ideal for minimal headroom
applications.
- Built-in Head vs. Flow tables for standard
weirs and flumes.
- 32-point linearization input for custom
applications
- No special wiring. Uses standard shielded
two-wire signal cable up to 2000 ft long.
• Temperature Range: -22° F to 150° F
• Weight: 1.5 Lbs.
• Options: Loop powered scalable 4-20mA
output, AC powered w/2 relay outputs, explosion
proof, dual sensor input |
. . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . |
|
|